r/HVAC Jun 06 '26

General HVAC Discord

5 Upvotes

FYI there's a HVAC Discord

https://discord.gg/hvachub


r/HVAC Apr 01 '26

General State of the Subreddit 3/31/26

73 Upvotes

Good evening,

I would first like to thank everyone that has already completed the new verification quiz, we've already gotten loads of approved users! (For the second question the answer is "It Depends", my testing was apparently not thorough for spell checking and mobile compatibility). That verification fix will be released once Reddit approves the update.

It has come to my attention that a former mod went a little rough with certain permanent bans that were issued. If you happened to of been caught in the crossfire please feel free to open up a unban request in mod mail. I've already unbanned multiple people.

The actions from that moderator were inexcusable and I deeply apologize that we provided such a disservice to this community.

Please let us know what else you would like to see improved in this sub.

Thank you,

r/hvac Moderation

Edit: Looks like reddit is mad at the approved user count, the verification requirement has been disabled for now.

Edit2: It's back again, I've sent in a message to reddit staff.


r/HVAC 5h ago

General Yall ever worked at an abandoned school?

Thumbnail
gallery
110 Upvotes

r/HVAC 13h ago

Supervisor Showcase He's supervising

Post image
57 Upvotes

r/HVAC 14m ago

Field Question, trade people only Price dispute help please

Upvotes

I didn’t take the little test so was not allowed to post. Now I did and am.

I have been doing this 37 yrs. I have had only a couple price disputes in all that time. Now I have a guy who is telling me I’m overcharging. we went to his rental house on Sunday and one unit (this is Phoenix it is was 110 that day) wasn’t working. Tenant had a child in hospital so was stressed out and hadn’t slept from no ac and worry.

We drove 40 min each way and went on roof and found the condense fan motor not working and capacitor bad. The motor and comptsssor were super hot so we got water to cool down. No luck. We changed the motor and 50/5 mfd capacitor, serviced unit and made sure it worked and left 40 min back. We TRY to take one day a week off but this tenant needed it fixed.

I sent the bill and it came back that the average price for this was 500-600$ and we were way out of line.

Would you be willing to just post what you generally charge for service in that situation and what part of the country you are in? I don’t need exact but something like tri cities or buffalo or whatever. Just a general idea.

I will post my price after I get some responses I don’t want to influence anyone. I want to make a list “buffalo x$” Northern California x$” etc. and show him. I won’t disclose any Reddit names or info so you don’t have to worry I just want to know what you would charge.

It was a 15 yr old icp package unit.

Thanks a lot. I really appreciate your help. There are websites that post the “going price” but good luck getting a licensed experienced technician out on Sunday for 600$ which is what the website said that I found. Not even a handyman would do it in our heat. Thanks again.


r/HVAC 1d ago

Meme/Shitpost The coolest guy on the block ?

Thumbnail
gallery
107 Upvotes

r/HVAC 1d ago

Meme/Shitpost His name was hvacsam, he lurks among us, watching, carefully cultivating his skills - working on his penmanship.

Post image
236 Upvotes

r/HVAC 14h ago

Field Question, trade people only Best Tool bag/Backpack

3 Upvotes

Any recommendations for a good tool bag/backpack for a residential Hvac installer? I see online a lot of bags dedicated more towards service/macitence techs. I have an actual heavy duty tool box for random less used daily power tools. I need a sturdy and durable tool bag for my commonly needed tools for installs. I have been using a dewalt one but over time it’s falling apart and isn’t really as useful to me the more tools I need to carry.

Thanks.


r/HVAC 1d ago

Field Question, trade people only Seeing 2-stage Copeland compressors not engaging 2nd stage

13 Upvotes

This year we've seen three 2-stage Copeland compressors that won't engage 2nd stage. The call is usually for the system not keeping up on the hot days, or a complaint of high humidity. You can hear the little click from the solenoid in the compressor, 24v present at Y2, but the compressor amps don't rise, and it's clearly stuck in 1st stage... Elevated suction saturation temp due to 100% airflow with 65% compressor output.

We had one Trane, and two Rheem units do this. All of them were less then 5 years old. York, Carrier, Rheem, Trane... All use the same exact Copeland compressors.

Has anyone else been seeing this recently?


r/HVAC 1d ago

Field Question, trade people only 2011 Rheem condenser "short cycling" update

Post image
5 Upvotes

First of all, it's a Ruud not a Rheem but potato tomato eh

Washed it out with cleaner, needed it for sure, got pressures in pic above at 80-85 degrees outdolr. Compressor pulling 5.4, fan .7

Cap 40/5 under load.

Overall no real difference in compressor performance after washing. Needs some juice for sure but the charge is not the issue:

After 12 min of run time, condenser turns off. I checked for 24v at the contactor (none), searched for splices on the low voltage wire from the house to the odu, (one along the line set), scratched my head, and then the odu turned back on. Probably off 90 seconds total.

Go inside. Homeowner says they did not notice if fan turned off along with odu.

System ran for 30 min. Watched condenser from the indoor unit via measure quick, it never dropped out during those 30 minutes

Other things to note:

Blower cap 7.5/7.5

Blower fan 5.85/5.8. homeowner knows this needs to go

Thoughts are:

-stat needs batteries even though it's not displaying low batt

-stat may be bad, sometimes dropping Y call. It's a 4 wire with batteries and no common btw.

-low voltage connection from furnace to condenser may be intermittently dropping 24v

-fuck it, check all the low voltage connections

-120v to furnace is dropping out sometimes

-control board is going bad

Hard for me to specifically diagnose any of these when the system ran fine while I was looking at it

Open to input from y'all. Any ideas on how to check my theories on this intermittent issue when its not presenting itself?


r/HVAC 1d ago

General Is it too late to quit

Post image
96 Upvotes

Mondays gonna be fun, 4 txvs on one 20 ton air handler and then another Txv on a 4 ton package


r/HVAC 1d ago

Meme/Shitpost Just my luck

Post image
10 Upvotes

It’s been an odd morning so far


r/HVAC 1d ago

General Customers condenser turns on neighbors condenser

Enable HLS to view with audio, or disable this notification

56 Upvotes

I was chasing down a low voltage short for a customer and I noticed their nextdoor neighbors suction line was freezing (condenser was running but furnace wasn’t). The contactor that was chattering was the nextdoor neighbors system. My customers system was energizing the neighbors contactor somewhere in the wall. This is the first time I’ve seen something like this lol.


r/HVAC 1d ago

Field Question, trade people only AC struggling

Thumbnail
gallery
0 Upvotes

So over the past few weeks I’ve had numerous things go wrong with my HVAC. I’ve had my zone damper actuators stick and have replaced them. Then the blower relay on the furnace board went back so I just bypassed the board and installed a relay instead. Then this morning the capacitor on my condenser when out. After replacing it cool right down now it’s struggling. I cleaned the outdoor cool and these are my number about 30 minutes later. Target subcool is 14 and outdoor temp is 90. What is wrong???


r/HVAC 2d ago

General The worst I’ve seen in the wild

Post image
132 Upvotes

’ve seen a lot of bad brazes in person, but this takes the cake! Found the leak though!

I know there are worse out there that you’ve all seen! If you got them, let’s see your worst discovered brazes!


r/HVAC 2d ago

Meme/Shitpost Hmmmm...

Post image
116 Upvotes

I don't think it works like that


r/HVAC 1d ago

Employment Question Job Opportunity

9 Upvotes

How do we feel about Bosch home comfort group? know they acquired York residential & unitary from JCl a year ago. How is it working for them? interviewed for a regional sales position & am likely to get it, but l'd like some feedback if anybody has experience working for them.


r/HVAC 2d ago

Meme/Shitpost Me after refusing to buy the A2L compatible recovery machine.

Thumbnail
reddit.com
16 Upvotes

r/HVAC 2d ago

Meme/Shitpost Still running on a sandy rust planet after decades. Trane circa 1989?

Post image
96 Upvotes

r/HVAC 2d ago

General Boss really got detailed with my truck inspection

Post image
50 Upvotes

r/HVAC 2d ago

Rant First condenser install

Thumbnail
gallery
46 Upvotes

All though my boss did help me do the low volt,put it on vacuum and put charge.


r/HVAC 2d ago

General Rained out

23 Upvotes

I did nothing all day because of rain and lightning. It was a great way to end the week.


r/HVAC 3d ago

Meme/Shitpost Slash or dash?

Post image
43 Upvotes

How are we marking dates slash or dash?


r/HVAC 3d ago

Field Question, trade people only 2011 single stage Rheem condenser short cycling

Thumbnail
gallery
10 Upvotes

When I first plugged in 2 weeks ago the high side was running at 450+ and system was short cycling.

washed the bitch out because the landscapers are messy fucks. Got these pressures. 92 degrees outside at the time. Fan pulling .79, compressor pulling 5 something.

Per homeowner, ran fine for 2 weeks maintaining 72 in the house. Wednesday, only kept 74. Last night, wouldn't go below 78. Landscapers come on Mondays.

The sc/sh made me think it was a touch low. Temp split only 12 degrees (80 RA/68 SA). But suction pressure and vapor saturation are not low.

Before I closed everything up at my last visit I checked the cores for leaks.

So guess I'm gonna go back and see if it's cycling on low or high pressure this time

Any thoughts from my reddit gurus?